Safety Precautions
*If this product is not used correctly, it may cause mild or moderate personal injury or material damage. *Do not connect the sensor to an alternating current power source, as there is a risk of explosion.
Standard Dimensions
Universal standard dimensions, interchangeable with multiple brands both domestically and internationally.
Built-in M3 metal threads enhance the body's fastening strength.

Designed with imported chips for faster response speed.
Anti-Interference
Optimized interference avoidance algorithm, stronger resistance to light and electromagnetic interference.
Designed with anti-mutual interference, allowing up to two sensors to be installed closely side by side.
Power Protection
Equipped with reverse connection protection to prevent sensor wiring faults.
Adjustable Sensitivity
Three-wire type, adjustable sensitivity, NO/NC switchable.
Simple optical axis adjustment, with the deviation between the optical axis and mechanical axis controlled within ±2.5°.
Kind
Red light
Infrared Light
| Detection Method | Shape | Connection Method | Detection Distance | Model | |
| NPN Output | PNP Output | ||||
| Through-Beam Type | ![]() | Lead-wire Type (2m) | 2m | EW-T21 | EW-T41 |
6m | EW-T61 | EW-T81 | |||
10m | EW-TA1000N | EW-TA1000P | |||
20m | EW-LT61 | EW-LT81 | |||
| Retroreflective Type | ![]() | 3m[100mm] | EW-R61 | EW-R81 | |
| Diffuse Reflective Type | ![]() | 5-100mm | EW-D61 | EW-D81 | |
600mm | EW-D62 | EW-D82 | |||
| Fine Beam Reflective Type | 300mm | EW-L61 | EW-L81 | ||
Rated Value
| Detection Method | Through-Beam Type | Retroreflective Type | Diffuse Reflective Type | |||||||
| Wide Field of View | Long Distance | Fine Beam | ||||||||
| Product Model | NPN Output Type | EW-T21 | EW-T61 | EW-TA1000N | EW-LT61 | EW-R61 | EW-D61 | EW-D62 | EW-L61 | |
| PNP Output Type | EW-T41 | EW-T81 | EW-TA1000P | EW-LT81 | EW-R81 | EW-D81 | EW-D82 | EW-L81 | ||
| Detection Distance | 2m | 6m | 10m | 20m | 3m[100mm] | 100mm | 600mm | 300mm | ||
| Detecting Objects | Opaque objects with a diameter of 12mm or more | Objects with a diameter of 75mm or more | Opaque, translucent, and transparent objects | |||||||
| Differential Distance | -- | Less than 15% of the detection distance. | ||||||||
| Repeat Accuracy | Within 0.5mm | Within 1mm | ||||||||
| Response Time | Within 1ms | Within 2ms | Within 1ms | |||||||
| Projection Element | Infrared LED | Red LED | Red laser | Red LED | Infrared LED | Red laser | ||||
| Directive Angle | 2~10° | -- | ||||||||
| Power Supply Voltage | DC12~24V±10%, Ripple (P-P) Below 5% | |||||||||
| Current Consumption | Within 35mA | Within 40mA | Within 35mA | Within 15mA | ||||||
| Control Output | Output form | <NPN Output Type> NPN Open Collector Transistor ・Maximum Sink Current: 100mA ・Applied Voltage: 30V DC or less (between output and 0V) ・Residual Voltage: 2V or less (at a sink current of 100mA) 1V or less (at a sink current of 50mA) | <PNP Output Type> PNP Open Collector Transistor ・Maximum Source Current: 100mA ・Applied Voltage: 30V DC or less (between output and +V) ・Residual Voltage: 2V or less (at a source current of 100mA) 1V or less (at a source current of 50mA). | |||||||
| Output Action | NO/NC Switchable | |||||||||
| Indicator Lights | Action indicator (orange), stable indicator (green) [The emitter of the Through-Beam Type only has a power indicator (orange)] | |||||||||
| Sensitivity Adjustment | Single-direction rotation knob | -- | Single-direction rotation knob | |||||||
| Anti-interference Function | Equipped with | |||||||||
| Power Protection | Equipped with reverse power connection protection, output short-circuit protection | |||||||||
| Protection Rating (IP Rating) | IP50(IEC) | |||||||||
| Environmental Performance | Environmental Illumination | Incandescent lamp below 3,000 Lux; Sunlight below 10,000 Lux | ||||||||
| Ambient Temperature | Operating: -25℃ to 55℃ Storage: -25℃ to 55℃ | |||||||||
| Ambient Humidity | Operating: 35% to 85%RH Storage: 35% to 85%RH(No Condensation) | |||||||||
| Insulation Resistance | 20MΩ or more (DC500V megohmmeter) | |||||||||
| Voltage Resistance | AC1,000V50/60Hz 1min | |||||||||
| Vibration Resistance | 10~55Hz, 1.5mm, double amplitude in X, Y, Z directions, 2 hours each | |||||||||
| Impact Resistance | 500 m/s2 X, Y, Z direction 3 times each | |||||||||
| Wiring Method | Lead-wire Type (standard line length 2m) | |||||||||
| Material | Outer Casing | Housing: ABS Lens: Transparent PC | ||||||||
| Cable | 0.2mm 22-core/3-core/4-core rubber cable, 2m in length | |||||||||
| Accessory Part | Instruction manual, screwdriver, reflector (retroreflective type) | |||||||||
| Weight | About120g | About 65g | ||||||||
1. When using the EW-R61/81, please set the distance between the sensor and the reflector to a value greater than that within [100mm].
2. The detection distance for the diffuse reflection type is the distance when detecting a white A4 paper.



User Guide
The following items are of great importance for ensuring safety. Please make sure to comply with them strictly:
(1) Do not use this product in an environment with flammable or explosive gases.
(2) Do not disassemble, repair, or modify this product.
(3) The power supply voltage must be within the rated range (DC 12 to 24V ±10%).
(4) Use a load that does not exceed the rated value.
Safety Key Points
(1) Do not use this product in the following places:
①Places directly exposed to sunlight.
②Places with high humidity or prone to condensation.
③Places containing corrosive gases.
④Places where vibration or impact can be directly transmitted to the sensor.
(2) Connection and Installation:
①The maximum allowable voltage of the sensor is DC 26.4V. Before powering on, please confirm that the supply voltage is lower than the maximum allowable voltage.
② When the sensor wire is used in the same sleeve as the power line or electrical line, it will be interfered with, which may lead to malfunction or even damage. In principle, the sensor wire must be placed separately or shielded.
③ The extended wire must be a wire with a cross-sectional area of more than 0.3 mm² and a length of no more than 100m. When using the Korean S-mark certified model as a certified product, the wire length should not exceed 10m.
④ The force applied to the wire part should be less than the following values: Tensile force not exceeding 80N, torque not exceeding 0.1N·m, pressing force not exceeding 20N, and bending force not exceeding 3kg.
⑤ When installing the sensor, do not apply severe external force to the sensor (such as hitting it with a hammer, etc.), otherwise it may damage the waterproof protection performance of the sensor. When installing, please use M3 bolts for fixing.
(3) Cleaning: Since diluents and the like will dissolve the surface of the product, please avoid using them. (4) Power Supply: When using a commercially available switching rectifier, please ground the FG (Frame·Ground terminal).
(5) Power Reset Time: The time from powering on to when the sensor can detect normally is 100ms. Therefore, please use it 100ms after powering on. When the load and the sensor are connected to different power sources, be sure to power on the sensor first.
(6) Power Off: When the power is turned off, output pulses may occur. Therefore, it is recommended to turn off the power of the load or the load line first.
(7) Disposal: When disposing of this product, please treat it as industrial waste.
Commitment Items during Use
(1) To ensure safety, do not use this product directly or indirectly for human body detection. If it is necessary to use it for this purpose, please select the safety sensor published in the comprehensive sample of our company's sensors.
(2) When using it for the following purposes, please consult with our company's application engineers, confirm according to the specification sheet, etc., and adopt a usage method with a certain margin relative to the rated performance, or take safety circuit measures that can minimize the degree of danger even in case of a failure:
a) When using it outdoors, in an environment with potential chemical pollution or electrical interference, or in conditions or environments not described in the product manual, instruction manual, etc.
b) When using it for atomic energy control equipment, incineration equipment, railways, aviation, vehicle equipment, medical equipment, entertainment devices, safety devices, and equipment manufactured in accordance with the regulations of administrative authorities or individual industries.
c) When using it for systems, machines, or devices that may endanger life or property.
d) When using it for gas, water supply, power supply systems, or highly reliable equipment such as 24-hour continuous operation systems.
e) When using it for other purposes that require a high level of safety based on the criteria of a) to d) above.
*The above content is part of the applicable conditions. Before use, please refer to the warranty and liability exemption items described in the latest version of the product catalogs and manuals such as our company's comprehensive product manual data.
Subcategory:
Key Words:
Square Photoelectric Sensor EW Series
Factory
Advantage
Eight Reasons to Choose Tengyuanxiang
Quality Assurance
All products strictly follow ISO9001 standards, ensuring 100% factory-out qualification. Backed by a minimum 1-year warranty.
Comprehensive Product Range
Nearly 40 series of automated parts, over 60,000 domestic and international products cover most automated equipment design needs.
Fast Delivery
Over 95% of products shipped within 1-7 days.
Zero Inventory Solution
No minimum order quantity (MOQ) requirement, reducing inventory burden.
High Cost-effectiveness
Prices are 40% lower than foreign competitors and 22% lower than domestic ones for the same products. Quantity-based discounts available, with continuous price reviews.
Customization
Tailored solutions by a professional engineering team to tackle technical challenges.
Reliable After-sales
Professional management for quick customer complaint resolution.
Free Shipping
All orders in the Chinese mainland enjoy free delivery.
FAQ
What are the regular maintenance tasks for a website?
Regular website maintenance work is the key to ensuring the website's security, stable operation and user experience. Maintenance work includes updating website content, checking and fixing website links, backing up data, conducting regular security checks, fixing vulnerabilities, and optimizing performance, etc. These tasks help ensure the long-term effective operation of the website and provide a good user experience.
What are the differences between UI and UX in website design?
UI (User Interface) and UX (User Experience) are two important aspects in website design. UI focuses on the appearance design, layout and visual elements of a website, while UX emphasizes the overall user experience and interaction on the website, including ease of use, navigation, interaction, etc. Excellent UI design usually enhances the UX experience of users.
What types of website hosting services are there?
Website hosting services can be classified into shared hosting, virtual private servers (VPS), dedicated servers and cloud hosting. Shared hosting refers to multiple websites sharing the resources of one server. VPS is a virtual dedicated server, while standalone servers are exclusive servers. Cloud hosting, on the other hand, provides hosting solutions based on cloud services. Each type has its own distinct features and applicable scenarios.
What is the function of a website traffic statistics tool?
Traffic statistics tools such as Google Analytics help analyze website visit data, including visitor sources, traffic volume and user behavior, etc. By understanding these data, website owners can understand their audience, adjust website content and design, enhance user experience, and increase conversion rates.