Liquid Detection in Pipes
-
Built-in Amplifier, Space-Saving
The built-in amplifier eliminates the need for separate amplifier and detection probe setup, saving space.Easy Installation
Installation is completed by securing the sensor to the pipe with a cable tie. The position can be easily readjusted if needed. -
Kind
Shape Connection Method Detection Distance Action Mode Model NPN PNP 
Lead-wire Type (2m)
5mm (Slot Width)NO/NC Switchable FF-UX613-1 FF-UX613P-1 Rated Value
Product Model FF-UX613-1 FF-UX613P-1 NPN Output NO/NC PNP Output NO/NC Operation Mode Light-Off ON, Light-On ON, Operation Mode Detection Object Liquid in the Tube (Detection may fail if the liquid has high viscosity or suspended particles) Applicable Tube Transparent Tube with Outer Diameter φ6~13 (Thickness Below 2mm) Power Supply Voltage 5~30V DC, Ripple (P-P) 10% max Current Consumption 25mA max Operation Indicator Red Status Indicator, Green Output Indicator Light Source (Emission Wavelength) Infrared LED (940nm) Response Time 100Us Switching Frequency 20Hz Connection Method Lead-Wire Type (Standard Cable Length 2m) Power Protection Reverse Connection Protection, Surge Absorption, Load Short-Circuit Protection Ambient Illuminance Incandescent Lamp: 8,000 Lux, Sunlight: 10,000 Lux Ambient Temperature Operating Temperature: -25℃~55℃, Storage Temperature: -40℃~85℃ (No Icing) Ambient Humidity Operating and Storage Humidity: 35%RH~85%RH Residual Voltage Below 1.0V max. (Load: 100mA, Cable Length: 2m) Insulation Resistance 50MΩ max. (DC500V) Between Conductive Parts and Housing Withstand Voltage AC 1000V 50/60Hz 1min. Between Conductive Parts and Housing Protection Rating (IP Rating) IP50 Housing Material ABS+PC -



-

-
Precautions
Features of Photoelectric Liquid Level Sensor:
●No mechanical moving parts, high reliability.
●Compact size, can be installed in any direction.
●High precision in liquid level control.
●Complies with safety standard requirements.Applications of Photoelectric Liquid Level Sensor:
●Water level control for electronic toilets.
●Pump control, water tower level control.
●Other appliances and equipment requiring liquid level control.Operating Environment for Photoelectric Liquid Level Sensor:
●Do not use outdoors.
●Do not use in places where water, oil, or chemicals are directly splashed. The housing cover is made of polycarbonate, which is particularly soluble in alkalis, aromatic hydrocarbons, and chlorinated aliphatic hydrocarbons. Avoid contact with such chemicals.
●Avoid using in places with direct sunlight, corrosive gases, or sea breeze.Operating Principle:
This sensor detects the presence or absence of liquid by utilizing the difference in refractive index between liquid and air.
①If there is no liquid in the tube, the light emitted from the emitter will be refracted by the tube and enter the receiver. (Light-On State)
②If there is liquid in the tube, the light emitted from the emitter will pass through the liquid and not enter the receiver. (Light-Off State) -
Photoelectric Liquid Level Sensor FF-UX Series
Subcategory:
Key Words:
Photoelectric Liquid Level Sensor FF-UX Series
Factory
Advantage
Eight Reasons to Choose Tengyuanxiang
Quality Assurance
All products strictly follow ISO9001 standards, ensuring 100% factory-out qualification. Backed by a minimum 1-year warranty.
Comprehensive Product Range
Nearly 40 series of automated parts, over 60,000 domestic and international products cover most automated equipment design needs.
Fast Delivery
Over 95% of products shipped within 1-7 days.
Zero Inventory Solution
No minimum order quantity (MOQ) requirement, reducing inventory burden.
High Cost-effectiveness
Prices are 40% lower than foreign competitors and 22% lower than domestic ones for the same products. Quantity-based discounts available, with continuous price reviews.
Customization
Tailored solutions by a professional engineering team to tackle technical challenges.
Reliable After-sales
Professional management for quick customer complaint resolution.
Free Shipping
All orders in the Chinese mainland enjoy free delivery.
FAQ
What are the regular maintenance tasks for a website?
Regular website maintenance work is the key to ensuring the website's security, stable operation and user experience. Maintenance work includes updating website content, checking and fixing website links, backing up data, conducting regular security checks, fixing vulnerabilities, and optimizing performance, etc. These tasks help ensure the long-term effective operation of the website and provide a good user experience.
What are the differences between UI and UX in website design?
UI (User Interface) and UX (User Experience) are two important aspects in website design. UI focuses on the appearance design, layout and visual elements of a website, while UX emphasizes the overall user experience and interaction on the website, including ease of use, navigation, interaction, etc. Excellent UI design usually enhances the UX experience of users.
What types of website hosting services are there?
Website hosting services can be classified into shared hosting, virtual private servers (VPS), dedicated servers and cloud hosting. Shared hosting refers to multiple websites sharing the resources of one server. VPS is a virtual dedicated server, while standalone servers are exclusive servers. Cloud hosting, on the other hand, provides hosting solutions based on cloud services. Each type has its own distinct features and applicable scenarios.
What is the function of a website traffic statistics tool?
Traffic statistics tools such as Google Analytics help analyze website visit data, including visitor sources, traffic volume and user behavior, etc. By understanding these data, website owners can understand their audience, adjust website content and design, enhance user experience, and increase conversion rates.
anna.wang@sztey.cn